顺达空调设备集团Shunda HVAC
Products
Solutions
Projects
News
Certificates
About Us
Contact Us
顺达空调设备集团Shunda HVAC

Leading manufacturer of industrial ventilation, air conditioning, and smoke exhaust systems. Established in 2005, exporting to 50+ countries worldwide.

Products

  • AHU Equipment
  • Fans & Blowers
  • Cooling Towers
  • Heat Exchangers
  • View All Products

Quick Links

  • About Us
  • Solutions
  • Projects
  • Certificates
  • News
  • Contact Us

Contact

  • +86 156 6600 7616

    Available 24/7

  • silvia@shundahvac.com
  • Dezhou, Shandong, China

© 2026 Shunda Air Conditioning Equipment Group Co., Ltd. All rights reserved.

Privacy PolicyTerms of Service
Emailsilvia@shundahvac.comWhatsApp+8615666007616Phone+8615666007616Facebookhttps://www.facebook.com/share/1Gj2iXL7kL/?mibextid=wwXIfrTikTokhttps://www.tiktok.com/@shunda_air_conditioningMessage/en/contact-us
  1. Home
  2. Products
  3. FP-WA Horizontal Concealed Fan Coil Unit Series
FP-WA Horizontal Concealed Fan Coil Unit Series
1 / 4
​PerformanceModelFP-34FP-51FP-68FP-85FP-102FP-136FP-170FP-204FP-238
Rated Airflow (m³/h)High34051068085010201360170020402380
Medium2603905106407701020128015301790
Low17026034043051068085010201190
Rated Cooling Capacity (W / Kcal/h)H1.82.73.64.55.47.2910.812.6
H1548232230963870464461927740928810836
​Rated Heating Capacity (Kw / Kcal/h)H2.74.055.46.758.110.813.516.218.9
H232234834644580569669288116101393216254
​Input Power (W)12PaH3752627696134152189228
30PaH44597287108156174212253
50PaH496684100118174210250300
Noise Level [dB(A)]12PaH373941434546485052
30PaH404244464748505254
50PaH424446474950525456
Water Flow Rate (Kg/h)3505106608009801280160019202230
Working Pressure (Kpa)303030304040404050
Number of Fans1234
Weight (Kg)WA171819222639434952
With return air box202223273044485458
Water Inlet/Outlet3/4”Internal Thread
Condensate Drain Pipe3/4”​External Thread
Power Supply220V/50Hz
Notes1、Cooling conditions:​ Inlet air dry bulb temperature: 27°C, wet bulb temperature: 19.5°C; Inlet water temperature: 7°C, water temperature difference: 5°C. 2、Heating conditions:​ Inlet air dry bulb temperature: 21°C; Inlet hot water temperature: 60°C; Hot water flow rate is the same as cooling conditions. 3、Pressure test:​ Units are pressure tested at 2.0 MPa (20 bar), with a maximum allowable working pressure of 1.6 MPa (16 bar). 4、Others:​ Four-pipe systems are also available (e.g., 1-heating-2-cooling, 2-heating-2-cooling, 3-heating-1-cooling configurations).

Product Introduction

Product Overview The FP-WA Horizontal Concealed Fan Coil Unit Series​ represents a premium line of HVAC solutions designed for seamless integration into suspended ceiling spaces. Its low-profile design does not compromise on performance, delivering efficient heating and cooling for medium to large commercial spaces. Design & Engineering Featuring a durable galvanized steel casing and high-efficiency copper tube/aluminum fin coils, the FP-WA series ensures optimal heat transfer and longevity. The unit is equipped with a low-noise centrifugal fan and a removable drain pan, simplifying maintenance.

Applications

  • Commercial Office Buildings:​ Providing zoned comfort in open-plan offices, meeting rooms, and executive suites.
  • Hospitality & Hotels:​ Ideal for quiet, individual climate control in guest rooms, lobbies, and restaurant areas.
  • Healthcare Facilities:​ Suitable for patient rooms and waiting areas requiring consistent, draft-free air distribution.
  • Retail Stores & Boutiques:​ Concealed installation maintains clean sightlines and aesthetic appeal.
  • Building Retrofits:​ Perfect for upgrading existing HVAC systems where ceiling void space is limited.

Related Products

FP-LA Vertical Concealed Fan Coil Series | High-Efficiency, Low-Noise AC Terminal Unit

FP-LA Vertical Concealed Fan Coil Series | High-Efficiency, Low-Noise AC Terminal Unit

FP Series Exposed Fan Coil Units: Vertical & Horizontal Types

FP Series Exposed Fan Coil Units: Vertical & Horizontal Types

Ultra-thin fan coil unit

Ultra-thin fan coil unit

Cassette Type Four-Way Blow Fan Coil Unit

Cassette Type Four-Way Blow Fan Coil Unit

FP-WA Horizontal Concealed Fan Coil Unit Series

The FP-WA Horizontal Concealed Fan Coil Unit Series​ is engineered for discreet, high-capacity climate control in suspended ceilings. Offering superior airflow and quiet operation, it’s the ideal solution for offices, hotels, and commercial renovations where space and aesthetics are paramount.

Advantages

  • Space-Saving Horizontal Design:​ Minimal installation depth maximizes plenum space for other services.
  • Whisper-Quiet Operation:​ Advanced fan and motor design ensures comfort without disruptive noise.
  • High Energy Efficiency:​ Optimized coil and fan performance reduce overall system operating costs.
  • Easy Installation & Access:​ Standardized connections and removable panels simplify setup and routine maintenance.
  • Robust Construction:​ Corrosion-resistant materials guarantee reliability and a long service life.

Send Inquiry