顺达空调设备集团Shunda HVAC
Home
Products
Solutions
Projects
News
Certificates
About Us
Contact Us
顺达空调设备集团Shunda HVAC

Leading manufacturer of industrial ventilation, air conditioning, and smoke exhaust systems. Established in 2005, exporting to 50+ countries worldwide.

Products

  • AHU Equipment
  • Fans & Blowers
  • Cooling Towers
  • Heat Exchangers
  • View All Products

Quick Links

  • About Us
  • Solutions
  • Projects
  • Certificates
  • News
  • Contact Us

Contact

  • +86 156 6600 7616

    Available 24/7

  • silvia@shundahvac.com
  • Dezhou, Shandong, China

© 2026 Shunda Air Conditioning Equipment Group Co., Ltd. All rights reserved.

Privacy PolicyTerms of Service
Emailsilvia@shundahvac.comWhatsApp+8615666007616Phone+8615666007616Facebookhttps://www.facebook.com/shundahvacTikTokhttps://www.tiktok.com/@shundaairMessage/en/contact-us
  1. Home
  2. Products
  3. Direct-coupled Centrifugal Fan
Direct-coupled Centrifugal Fan
1 / 2

Specifications

Model No.

Speed(rpm)

Pressure(Pa)

Airflow(m³/h)

Power(kw)

2.8A

2900 

994~606

1131~2356

15 

3.2A

2900 

1300~792

1688~3517

2.2 

1450 

324~198

844~1758

1.1 

3.6A

2900 

1578~989

2664~5268

3 

1450 

393~247

1332~2634

1.1 

4A

2900 

2014~1320

4012~7419

5.5 

1450 

501~329

2006~3709

1.1 

45A

2900 

2554~1673

5712~10562

7.5 

1450 

634~416

2856~5281

1.1 

5A

2900 

3187~2019

7728~15455

15 

1450 

790~502

3864~7728

2.2 

6A

1450 

1139~724

6677~13353

4 

960 

498~317

4420~8841

1.5 

6D

1450 

1139~724

6677~13353

4 

960 

498~317

4420~8841

1.5 

8D

1450 

2032~1490

15826~29344

18.5 

960 

887~651

10478~19428

5.5 

730 

512~376

7968~14773

3 

10D

1450 

3202~2532

40441~56605

55 

960 

1395~1104

26775~37476

18.5 

730 

805~637

20360~28497

7.5 

12D

960 

   2013~1593

46267~64759

45 

730 

   1160~919

35182~49244

18.5 

6C

2240 

   2734~1733

10314~20628

15 

2000 

   2176~1380

9209~18418

11 

1800 

1760~1116

8288~16576

7.5 

1600 

   1389~881

7367~14734

5.5 

1250 

846~537

5756~11511

3 

1120 

679~431

5157~10314

2.2 

1000 

541~344

4605~9209

2.2 

900 

438~278

4144~8288

1.5 

800 

346~220

3684~7367

1.1 

8C

1800 

3143~2302

19646~36427

30、37

1600 

2478~1816

17463~32380

22、30

1250 

1507~1106

13643~25297

11 

1120 

1209-887

12224~22666

7.5、11

1000 

963~707

10914~20237

5.5、7.5

900 

779~572

9823~18213

4、5.5

800 

615~452

8732~16190

3 

710 

485~356

7749~14368

2.2、3

630 

381~280

6876~12749

2.2 

12C

1120 

2746~2172

53979~75552

75 

1000 

2185~1729

48195~67457

45、55

900 

1767~1399

43375~60712

37 

800 

1395~1104

38556~53966

22、30

710 

1097~869

34218~47895

18.5 

630 

863~684

30362~42498

15 

560 

682~540

26989~37776

7.5、11

500 

543~430

24097~33728

7.5 

450 

440~348

21687~30356

4、5.5

400 

347~275

19278~26983

3 

16B

900 

3157~2497

102810~143910

132、160

800 

2489~1969

91392~137920

110 

710 

1957~1549

81110~113520

75 

630 

1538~1218

71971~100730

55 

560 

1214~961

63974~89544

37 

500 

967~766

57120~79950

30 

450 

783~620

51408~71955

18.5 

400 

618~490

45696~63960

15 

355 

487~386

40555~56764

11 

315 

383~303

35985~50368

7.5 

20B

710 

3069~2427

158410~221730

220 

630 

2411~1908

140560~196750

160 

560 

1902~1505

124950~174890

110 

500 

1514~1199

111560~156150

75 

450 

1225~970

100400~140530

55 

400 

967~766

89250~124920

37 

355 

761~603

79209~110860

30 

315 

599~475

70284~98376

22 

280 

473~375

62475~87445

15 

250 

377~299

55781~78076

11 

Show only some parameters

Product Introduction

This direct-coupled centrifugal fan is a compact, self-contained air-moving unit in which the impeller is mounted directly onto the extended shaft of the driving motor, eliminating the need for belts, pulleys, bearing pedestals, and belt tensioning mechanisms. The motor and impeller share a common baseplate, resulting in a significantly reduced footprint compared to belt-driven equivalents of similar performance. The fan housing is fabricated from heavy-gauge carbon steel sheet, with continuously welded seams and integrally formed flanges at both the inlet and outlet openings. External stiffening ribs are welded to the housing shell to prevent panel vibration and maintain dimensional stability under fluctuating static pressure conditions. The impeller is of the backward-inclined or radial-blade type, depending on the specified duty point, and is individually dynamically balanced to ISO 1940 G6.3 grade or better, ensuring smooth operation with residual unbalance forces minimized. The motor is selected to match the impeller power demand at the design operating point and is mounted on a slotted adjustable baseplate that allows precise axial and radial alignment between the motor shaft and the housing inlet cone. A close-clearance running gap is maintained between the impeller eye and the inlet bell mouth to maximize aerodynamic efficiency and prevent recirculation losses. The complete rotating assembly — impeller, motor shaft, and motor rotor — is supported by sealed deep-groove ball bearings housed within the motor end shields, which are pre-packed with lithium-based grease for extended lubrication intervals. Access to the impeller chamber is provided through a bolted or hinged side access door, sized to allow removal of the impeller without disturbing the attached ductwork. The fan casing is fitted with lifting lugs or tapped holes for overhead crane handling during installation or maintenance. Electrical termination is via a weatherproof junction box mounted on the motor frame, with cable entry via threaded conduit ports. Each completed fan assembly is subjected to a factory acceptance test that includes no-load run-in for four hours, measurement of vibration velocity and displacement at bearing housings, verification of rotational speed using a non-contact tachometer, and documentation of actual voltage, current, and power consumption against the rated nameplate values. After testing, all external surfaces are cleaned, degreased, and coated with a two-component epoxy primer and polyurethane topcoat in a standard RAL color. The fan is then crated for export shipment with all loose items — such as gaskets, fasteners, and installation manuals — packed inside the shipping container.

Advantages

🔹 Compact Design​ — Motor and impeller are directly mounted on the same shaft, eliminating belt drives and external pulley systems. This reduces overall footprint and simplifies installation in tight spaces.

🔹 Maintenance-Free Operation​ — No belts to replace, no tension adjustments needed. Bearings are pre-lubricated and sealed, minimizing routine servicing and downtime.

🔹 High Reliability & Stability​ — Direct coupling ensures precise alignment between motor and fan, reducing vibration and wear. Ideal for continuous-duty applications.

🔹 Low Noise & Smooth Running​ — Elimination of belt slippage and misalignment results in quieter operation and longer component lifespan.

🔹 Energy Efficient​ — Eliminates power loss from belt friction and slippage; direct mechanical transfer improves overall system efficiency.

🔹 Easy Integration​ — Standard motor mounting dimensions allow quick replacement or retrofitting into existing ductwork or housing without major modifications.

🔹 Dust & Debris Resistant​ — Sealed bearing housings and enclosed motor design prevent contamination from entering critical components.

🔹 Wide Range of Applications​ — Suitable for HVAC, dust collection, boiler draft, tunnel ventilation, pneumatic conveying, and industrial exhaust systems.

🔹 Customizable Options​ — Available with various impeller materials (steel, stainless steel, aluminum), motor power ratings, and voltage configurations.

🔹 Compliance Ready​ — Designed to meet common international standards (ISO, CE, ATEX where applicable) for industrial safety and performance.

Applications

  • General supply and exhaust ventilation in manufacturing plants, assembly halls, and warehouses where floor space is at a premium and belt-drive overhang cannot be accommodated.
  • Dedicated dust extraction networks serving individual woodworking machines, metal grinding stations, or central baghouse systems where direct-drive reliability reduces downtime risk.
  • Boiler forced draft systems delivering combustion air to oil, gas, or solid-fuel burners in industrial boiler houses and packaged steam generators.
  • Induced draft systems drawing flue gases from small to medium-capacity furnaces, incinerators, and thermal oxidizers.
  • Tunnel ventilation systems for road, rail, or pedestrian subways where fan banks must fit within narrow ceiling voids or sidewall niches.
  • Auxiliary mine ventilation providing primary or booster fresh air flow to working faces in underground mineral extraction operations.
  • Clean air recirculation and exhaust in food processing facilities, pharmaceutical cleanrooms, and electronics assembly areas where particle shedding from belt wear must be avoided.
  • Process air movement in cement plant raw mill circuits, foundry shakeout decks, and glass furnace regenerator chambers.
  • Pneumatic conveying lines transporting powdered, granular, or pelletized materials over moderate distances at controlled velocities.
  • HVAC make-up air units and dedicated outdoor air systems serving commercial office buildings, educational institutions, and healthcare facilities.
  • Retrofit replacement of existing belt-driven fans in aging infrastructure where conversion to direct-drive configuration yields measurable reductions in energy consumption, spare parts inventory, and maintenance labor hours.
  • Marine and offshore ventilation of engine rooms, pump rooms, and cargo holds where compactness and spark-proof construction are mandatory.

Related Products

F9-26 Centrifugal Induced Draft Fan | High Pressure Boiler Exhaust

F9-26 Centrifugal Induced Draft Fan | High Pressure Boiler Exhaust

F9-19 FRP Acid & Alkali Resistant Fan | Anti-Corrosion Fiberglass Ventilator

F9-19 FRP Acid & Alkali Resistant Fan | Anti-Corrosion Fiberglass Ventilator

FRP 4-72 Industrial Centrifugal Fan

FRP 4-72 Industrial Centrifugal Fan

Industrial Low Noise Carbon Steel Centrifugal Fan

Industrial Low Noise Carbon Steel Centrifugal Fan

Direct-coupled Centrifugal Fan

Compact direct-coupled centrifugal fan with integrated motor, eliminating belts and pulleys. Ideal for industrial ventilation, dust collection, and HVAC systems requiring low maintenance and stable airflow.

Send Inquiry