顺达空调设备集团Shunda HVAC
Home
Products
Solutions
Projects
News
Certificates
About Us
Contact Us
顺达空调设备集团Shunda HVAC

Leading manufacturer of industrial ventilation, air conditioning, and smoke exhaust systems. Established in 2005, exporting to 50+ countries worldwide.

Products

  • AHU Equipment
  • Fans & Blowers
  • Cooling Towers
  • Heat Exchangers
  • View All Products

Quick Links

  • About Us
  • Solutions
  • Projects
  • Certificates
  • News
  • Contact Us

Contact

  • +86 156 6600 7616

    Available 24/7

  • silvia@shundahvac.com
  • Dezhou, Shandong, China

© 2026 Shunda Air Conditioning Equipment Group Co., Ltd. All rights reserved.

Privacy PolicyTerms of Service
Emailsilvia@shundahvac.comWhatsApp+8615666007616Phone+8615666007616Facebookhttps://www.facebook.com/shundahvacTikTokhttps://www.tiktok.com/@shundaairMessage/en/contact-us
  1. Home
  2. Products
  3. T4-72 Industrial Centrifugal Ventilation Fan
T4-72 Industrial Centrifugal Ventilation Fan

Specifications

Model No.

Speed

(rpm)

Pressure
(Pa)

Airflow
(m³/h)

Power
(kw)

3A

2900 

1142~716

1588~3049

1.5 

1450 

285~175

794~1524

0.75 

3.5A

2900 

1556~976

2522~4841

3 

1450 

388~243

1261~2421

1.1 

4A

2900 

2036~1276

3764~7226

5.5 

1450 

506~318

1882~3613

1.1 

4.5A

2900 

2582~1616

5360~10288

7.5 

1450 

641~402

2680~5144

1.1 

5A

2900 

3195~1998

7352~14113

11、15

1450 

792~497

3676~7057

2.2 

6A

1450 

1142~716

6352~12194

4 

960 

499~313

4206~8073

1.5 

7C

1800 

2406~1506

12521~24038

15、18.5

1600 

1897~1189

11130~21367

11 

1250 

1155~724

8696~16693

5.5 

1120 

927~581

7791~14957

4 

1000 

738~463

6957~13354

3 

900 

598~375

6261~12019

3 

800 

472~296

5565~10683

2.2 

710 

372~233

4939~9482

1.5 

8C

1800 

3150~1970

18691~35882

30、37

1600 

2483~1554

16614~31895

22 

1250 

1511~947

12980~24918

11 

1120 

1211~760

11630~22326

7.5 

1000 

965~605

10384~19934

5.5 

900 

781~490

9346~17941

4 

800 

617~387

8307~15947

3 

710 

486~305

7373~14153

2.2 

630 

382~240

6542~12558

1.5 

10C

1300 

2551~1621

37328~50807

37 

1170 

2063~1311

24595~45726

30 

1040 

1627~1035

21862~40645

18.5 

940 

1328~845

19760~36737

15 

830 

1034~658

17447~32438

11 

740 

822~523

15556~28921

7.5 

660 

653~416

13874~25794

5.5 

580 

504~321

12192~22667

4 

520 

405~258

10931~20322

3 

12C

1170 

2980~1892

42500~79015

75 

1040 

2349~1493

37778~70236

55 

940 

1916~1218

34145~63482

37 

12C

830 

1492~949

30150~56053

22、30

740 

1185~754

26880~49975

18.5 

660 

942~599

23974~44572

15 

580 

727~463

21068~39170

11 

520 

584~372

18889~35118

7.5 

470 

477~304

17072~31741

5.5 

420 

381~242

15256~28364

4 

 Show only some parameters

Product Introduction

Rotation Form

Viewed from the motor‑side end, an impeller rotating clockwise is defined as a right‑hand fan, marked “Right”; an impeller rotating counter‑clockwise is defined as a left‑hand fan, marked “Left”.

The outlet direction of the fan is specified by the casing outlet angle.

• For Model 4‑72 fans No.2.8‑6: Only one outlet orientation is manufactured before delivery. Please specify the required outlet position at the time of order.

• Outlet angle adjustment range for No.2.8‑12: 0°~225°, in intervals of 45°.

• Outlet angle adjustment range for No.3.2‑6: 0°~225°, in intervals of 45°.

• Three fixed outlet positions (0°, 90°, 180°) are available for No.16‑20, which are non‑adjustable and shall be specified when ordering.

Four drive types are available: A, B, C, D.

• No.2.8‑6 of 4‑72 fans adopt Type‑A drive

• No.8‑12 adopt Type‑C / D drive

• No.16‑20 adopt Type‑B drive

Structural Features

Fans No.2.8‑6 are mainly composed of impeller, casing and inlet nozzle, directly coupled to the motor.Fans No.8‑20 contain the above‑mentioned components plus the drive assembly.

(1) The impeller consists of 10 backward‑inclined airfoil‑shaped blades, curved front plate and flat rear plate. It is fabricated from copper‑plate or cast‑aluminum alloy, and treated with static‑balance and dynamic‑balance correction. It delivers favorable aerodynamic performance, high efficiency and smooth‑running operation.

(2) Two casing configurations are available:

• No.2.8‑12: The volute casing is manufactured as an integral, non‑detachable unit.

• No.16‑20: Split‑type casing, divided along the horizontal centerline, fastened with bolts.

(3) The integral converged inlet nozzle is mounted on the side of fan casing, connected axially in parallel. Its curved‑profile cross‑section enables smooth gas entry into the impeller with low flow loss.

(4) The drive assembly is made up of main shaft, bearing housing, rolling bearings, belt pulley or coupling.

Performance & Selection

This manual only provides dimensionless performance tables and curves for fan No.10.

The dimensional performance parameters for fans larger than No.10 can be calculated from these data.

Advantages

🔧 Robust Carbon Steel Construction​ — Welded housing resists corrosion and mechanical stress for long-term durability in harsh environments.

⚙️ Precision-Balanced Radial Impeller​ — High-accuracy balancing ensures smooth, pulsation-free airflow and stable pressure performance.

🔄 Dual Drive Options​ — Available with direct drive or belt drive for flexible matching to motor power and speed requirements.

🔌 Standard Flange Mounting​ — Compatible with industrial ductwork and HVAC systems for seamless integration.

🔍 Easy Maintenance Access​ — Removable access panels and inspection hatches allow quick servicing without full disassembly.

🌍 Global Compliance Ready​ — Meets international mechanical safety and material standards for deployment in regulated industries.

📦 Factory Tested & Calibrated​ — Each unit undergoes pre-shipment testing for balance, leakage, and performance consistency.

🔩 Spare Parts Availability​ — Blades, bearings, and seals are stocked globally to minimize operational downtime.

Applications

  • This fan is engineered for a wide range of fixed-installation applications where reliable, continuous airflow is critical. Typical uses include general industrial ventilation in manufacturing plants, forced-air circulation in warehouses and logistics centers, exhaust and supply air systems in mechanical rooms, pressurization of stairwells and underground facilities, and integration into HVAC systems for commercial buildings. It is also suitable for agricultural drying systems, tunnel ventilation, and process cooling setups where moderate to high static pressure is required. The fan’s standardized design allows for seamless retrofitting into existing ductwork or new construction projects.

Related Products

F9-26 Centrifugal Induced Draft Fan | High Pressure Boiler Exhaust

F9-26 Centrifugal Induced Draft Fan | High Pressure Boiler Exhaust

F9-19 FRP Acid & Alkali Resistant Fan | Anti-Corrosion Fiberglass Ventilator

F9-19 FRP Acid & Alkali Resistant Fan | Anti-Corrosion Fiberglass Ventilator

FRP 4-72 Industrial Centrifugal Fan

FRP 4-72 Industrial Centrifugal Fan

4-72 High Efficiency Centrifugal Fan

4-72 High Efficiency Centrifugal Fan

T4-72 Industrial Centrifugal Ventilation Fan

4‑72 centrifugal fan is used for ventilation of general factories and large‑scale buildings. It conveys air and other non‑self‑ignitable, harmless and non‑corrosive gases. No sticky substances are permitted in the gas. The content of dust and hard‑granular solids shall not exceed 150 mg/m³, and the gas temperature shall not exceed 80 ℃.Featuring a robust carbon steel housing, precision-balanced impeller, and low noise operation, this fan delivers stable airflow and consistent static pressure under continuous duty conditions. Equipped with standard flange connections for easy duct attachment and accessible inspection ports for simplified maintenance, the 4-72 series offers long service life with minimal upkeep. Suitable for general ventilation, exhaust, air circulation, and process cooling applications in a wide range of industrial and commercial environments.

Send Inquiry